ELECTRICAL STEAM BOILERHEAVY DUTY ELECTRICAL STEAM BOILERS |
|
Type DH
The DH is a "heavy duty" boiler which means that the design is very rigid and reliable i operation. It leaves no compromises on quality are accepted and where low purchase price are not the key words. Compared to other electrical steam boiler on the market, the DH has a substantial longer lifetime. Many customers claim: "You cannot kill it!". DH electrical steam heaters are available as Clean Steam generators, i.e. sanitary and pharmaceutical design.
. |
AB&CO · TT BOILERS
are a well-known Danish electrical steam boiler manufacturer, who have specialised in small and medium size customised heaters and boilers.
Skid-mounted Electrical Boiler DH
Often the boilers are delivered skid-mounted with feed water tank, water treatment and blow-down facility as shown above (type DH) TT BOILERS also manufacture sophisticated boilers with the special and extensive triple redundent safety with two parallel PLCs - making superheated steam for power plants (gland heating for turbines) at PGT, Isle of Man, UK: Photo1 Photo2 (type DH2). |
Type DH2
DH2 electrical steam heaters are available as Clean Steam generators, i.e. sanitary and pharmaceutical design. The DH2 is also a "heavy duty" boiler which means that the design is very rigid and reliable i operation. It leaves no compromises on quality are accepted and where low purchase price are not the key words.
|
|
|
||||
![]() type DH |
|
|||
|
||||
| ELECTRICAL STEAM BOILER | type DH | |||||||||||
| 12X | 12 | 19,5 | 39 | 58,5 | 78 | 97,5 | 117 | 136,5 | 156 | |||
| Nominal Output ( = Consumed Power) | kW | 12 | 12 | 19,5 | 39 | 58,5 | 78 | 97,5 | 117 | 136,5 | 156 | |
| Current at 3 x 400 V | A | 17,3 | 17,3 | 28,1 | 56,3 | 84,4 | 112,6 | 140,7 | 168,9 | 197 | 225 | |
|
Steam
Capacity at 6 bar and Feed Water Temperature 20°C |
kg/h | 16 | 16 | 26 | 52 | 78 | 104 | 130 | 155 | 181 | 207 | |
|
Steam
Capacity at 6 bar and Feed Water Temperature 90°C |
kg/h | 18 | 18 | 29 | 58 | 87 | 116 | 145 | 175 | 204 | 233 | |
| Total Volume | L | 10 | 30 | 100 | ||||||||
| Weight - Empty | kg | 125 | 145 | 200 | ||||||||
| Weight - Service | kg | 135 | 175 | 300 | ||||||||
| Width | W | mm | 750 | 750 | 900 | |||||||
| Depth | D | mm | 600 | 950 | 1100 | |||||||
| Height | H | mm | 2050 | 2150 | 2250 | |||||||
| Connection - Feed Water | DN | mm |
15 1/2" |
|||||||||
|
Connection
- Low Pressure Steam Design Pressure 1 bar gauge |
DN | mm |
20 3/4" |
32 5/4" |
50 2" |
|||||||
|
Connection
- High Pressure Steam Design Pressure 6 bar gauge |
DN | mm |
20 3/4" |
25 1" |
||||||||
| ELECTRICAL STEAM BOILER | type DH2 | |||||||||||
| 195 | 234 | 273 | 312 | 351 | 390 | 429 | 468 | 507 | 585 | |||
| Nominal Output ( = Consumed Power) | kW | 195 | 234 | 273 | 312 | 351 | 390 | 429 | 468 | 507 | 585 | |
| Current at 3 x 400 V | A | 281 | 338 | 394 | 450 | 507 | 562 | 619 | 675 | 732 | 844 | |
|
Steam
Capacity at 6 bar and Feed Water Temperature 20°C |
kg/h | 255 | 305 | 355 | 405 | 455 | 510 | 560 | 610 | 660 | 785 | |
|
Steam
Capacity at 6 bar and Feed Water Temperature 90°C |
kg/h | 285 | 340 | 400 | 455 | 515 | 570 | 630 | 685 | 740 | 885 | |
| Total Volume | L | 400 | 560 | 745 | ||||||||
| Weight - Empty | kg | 500 | 670 | 730 | ||||||||
| Weight - Service | kg | 900 | 1230 | 1475 | ||||||||
| Diameter | D | mm | 800 | 900 | 1000 | |||||||
| Width | W | mm | 1160 | 1260 | 1360 | |||||||
| Length | L | mm | 2050 | 2100 | 2150 | |||||||
| Height | H | mm | 1250 | 1350 | 1450 | |||||||
|
Connection
- Low Pressure Steam Design Pressure 1 bar gauge |
DN |
mm - |
50 2" |
65 2 1/2" |
80 3" |
|||||||
|
Connection
- High Pressure Steam Design Pressure 6 bar gauge |
DN |
mm - |
25 1" |
32 5/4" |
40 1 1/2" |
50 2" |
||||||
|
Connection
- High Pressure Steam Design Pressure 10 bar gauge |
DN |
mm - |
25 1" |
32 5/4" |
40 1 1/2" |
|||||||